RENT / TRILOGY MASTER MIND

€100.00
Tax excluded

Designed to complement the Mentor and Mentor Plus units, The

Mastermind  changeover  actively  monitors  the  condition  of  both

analogue  and  digital  reference  and  test  signals.  Option  boards

may be used to configure the unit to individual requirements. As

standard  the  unit  monitors  one  pair  of  main  and  reserve  black

burst inputs and includes changeover of these signals plus relay

changeover of three pairs of other signals.

Option modules include:

330-01-00 Black burst monitor and changeover board

330-02-00 SDI monitor and changeover board (Alsopasses embedded audio)

330-06-00 AES audio monitor and changeover board

330-03-00 Three pair relay changeover board

Black and Burst

Sync Detection Fail indicated for sync <3.5dB ±0.75dB

Burst Detection Fail indicated for burst <3.5dB ±0.75dB

Changeover By relay, power fail defaults to input A

Return Loss <-48dB

Crosstalk between A&B <-65dB 0-5.5MHz

Serial Digital Video

Changeover By D1 serial receiver/driver, power fail defaults to input 'A' by battery back-up when enabled

Output Return Loss <-48dB

Input Return Loss <-14dB

Crosstalk between A&B <-40dB @ 270MHz

Video and Pulse Switching

Changeover By Relay

Return Loss <-48dB

Crosstalk between A&B <-65dB 0-5.5MHz

Remote Alarm Outputs

Type Open Collector

Maximum Voltage 50V DC

Maximum Current 500mA

General Details

Battery Life 2hr approx. when 1 off 330-02 fitted. 1 hr approx. when 2 off 330-02 fitted

Height 44mm(1RU)

Depth (not including connectors) 425mm

Width (including rack ears) 483mm (19" rack mounting)

Width (not including rack ears) 450mm

Weight (without options fitted) 3.5Kg